Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 25
Filter
1.
Article in Spanish | LILACS, UY-BNMED, BNUY | ID: biblio-1520020

ABSTRACT

La sífilis es causada por Treponema pallidum, es reconocida por la variedad de sus manifestaciones clínicas; compromete el sistema nervioso, tegumentario y cardiovascular. Las alteraciones cardiovasculares ocurren en 70% de los casos con sífilis no tratada, el 71% de las aortitis sifilíticas desarrollan aneurismas aórticos y la complicación más frecuente es la insuficiencia aórtica. El tratamiento va dirigido a la enfermedad subyacente, con manejo antibiótico para la sífilis terciaria y las complicaciones tromboembólicas y si requiere reparación quirúrgica. Presentamos un caso poco frecuente de un paciente diagnosticado de infección por el virus de la inmunodeficiencia humana y complicaciones cardiovasculares típicas de la sífilis terciaria, que precisó tratamiento médico y quirúrgico, que fue exitoso. Destacamos la pericia clínica de los profesionales de nuestra institución para diagnosticar e identificar las complicaciones cardiovasculares de la sífilis terciaria.


Syphilis is caused by Treponema pallidum and is recognized by the variety of its clinical manifestations; it involves the nervous, integumentary and cardiovascular systems. Cardiovascular alterations occur in 70% of cases with untreated syphilis, 71% of syphilitic aortitis develop aortic aneurysms and the most frequent complication is aortic insufficiency. Treatment is directed at the underlying disease, with antibiotic treatment for tertiary syphilis and thromboembolic complications and if necessary surgical repair. We present a rare case of a patient diagnosed with human immunodeficiency virus infection and cardiovascular complications typical of tertiary syphilis, who required medical and surgical treatment, which was successful. We highlight the clinical experience of our institution's professionals in the diagnosis and identification of cardiovascular complications of tertiary syphilis.


A sífilis é causada pelo Treponema pallidum e é reconhecida pela variedade de suas manifestações clínicas; ela afeta os sistemas nervoso, tegumentar e cardiovascular. As alterações cardiovasculares ocorrem em 70% dos casos de sífilis não tratada, 71% dos casos de aortite sifilítica desenvolvem aneurismas aórticos e a complicação mais frequente é a insuficiência aórtica. O tratamento é direcionado para a doença subjacente, com tratamento antibiótico para sífilis terciária e complicações tromboembólicas e, se necessário, reparo cirúrgico. Apresentamos um caso raro de um paciente diagnosticado com infecção pelo vírus da imunodeficiência humana e complicações cardiovasculares típicas da sífilis terciária, que precisou de tratamento médico e cirúrgico, que foi bem-sucedido. Apresentamos um caso raro de um paciente com diagnóstico de infecção pelo vírus da imunodeficiência humana e complicações cardiovasculares típicas da sífilis terciária, que necessitou de tratamento médico e cirúrgico, o qual foi bem-sucedido. Destacamos a experiência clínica dos profissionais de nossa instituição no diagnóstico e na identificação das complicações cardiovasculares da sífilis terciária.


Subject(s)
Humans , Male , Adult , Aortic Aneurysm/surgery , Aortic Aneurysm/diagnostic imaging , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Aneurysm/etiology , Aortic Valve Insufficiency/etiology , Penicillin G Benzathine/therapeutic use , Syphilis, Cardiovascular/complications , Syphilis, Cardiovascular/diagnosis , Syphilis, Cardiovascular/drug therapy
2.
ABC., imagem cardiovasc ; 35(2): eabc304, 2022. ilus, tab
Article in Portuguese | LILACS | ID: biblio-1400334

ABSTRACT

Introdução: A função sistodiastólica do ventrículo esquerdo é prognóstica nas doenças cardiovasculares e pode ser avaliada por strain longitudinal global por meio de ecocardiografia e de ressonância magnética cardíaca. O strain longitudinal global pela ressonância magnética cardíaca exige a utilização de software de alto custo. O deslocamento linear longitudinal do ventrículo esquerdo pode ser uma alternativa simples e barata ao strain longitudinal global, porém eles não foram ainda comparados sistematicamente. Objetivo: Comparar o deslocamento linear longitudinal com o strain longitudinal global e fração de ejeção do ventrículo esquerdo em valvopatas aórticos e controles. Métodos: Incluímos 44 participantes (26 valvopatas aórticos/19 controles). O strain longitudinal global utilizou software específico (Circle Cardiovascular Imaging 42) e o deslocamento linear longitudinal apenas medidas lineares de distância entre a base e o ápex do ventrículo esquerdo, gerando deslocamento máximo, velocidade máxima no início da diástole, velocidade na diástase e a relação entre velocidade na diástase e velocidade máxima no início da diástole. Resultados: Deslocamento máximo e velocidade máxima no início da diástole correlacionaram-se com strain longitudinal global (r=0,69 e r=0,65 respectivamente) e com a fração de ejeção do ventrículo esquerdo (r=0,47 e r=0,57, p<0,001 para ambos). Deslocamento máximo e velocidade máxima no início da diástole apresentaram área sob a curva Característica de Operação do Receptor de 0,88 e 0,91 e, no melhor ponto de corte (-0,13 e 0,66), sensibilidade de 72,43% e 57,14% e especificidade 80,65% e 87,10%, respectivamente, quando comparados ao strain longitudinal global. Utilizando a fração de ejeção do ventrículo esquerdo como referência, foram obtidos 0,70 e 0,82, e, no melhor ponto de corte (-0,11 e 0,61), sensibilidade de 75,00% e 50,00% e especificidade 72,97% e 78,38%, respectivamente. Conclusão: O deslocamento linear longitudinal foi semelhante ao strain longitudinal global. O deslocamento máximo derivado do deslocamento linear longitudinal foi o melhor parâmetro na sístole, enquanto a velocidade máxima no início da diástole foi o melhor na diástole, o que possibilita a avaliação da função diastólica pela ressonância magnética cardíaca na rotina clínica de forma rápida e sem custo adicional.(AU)


Background: Left ventricular (LV) systolic diastolic function is prognostic in cardiovascular diseases and can be assessed via global longitudinal strain (GLS) on echocardiography and cardiac magnetic resonance (CMR). However, GLS by CMR requires the use of expensive software. Longitudinal linear displacement (LLD) may be a simple and inexpensive alternative to GLS, but the two have not been systematically compared. Objective: To compare LLD with GLS and LV ejection fraction (LVEF) in aortic valve disease patients and controls. Methods: We included 44 participants (26 with aortic valve disease, 19 controls). GLS was determined using CVI42 software (Circle Cardiovascular Imaging), while the LLD linear measurements of the distance between the base/apex of the LV included maximum displacement (MD), maximum velocity in early diastole (MVED), atrioventricular junction velocity in diastasis (VDS), and VDS/MVED ratio. Results: DM and MVED were correlated with GLS (r=0.69 and r=0.65, respectively) and LVEF (r=0.47 and r=0.57, p<0.001 for both). DM and MVED showed areas under the receiver operating characteristic curve (AUC) of 0.88 and 0.91, and at the best cut-off point (-0.13 and 0.66), sensitivities of 72.43% and 57.14% and specificities of 80.65% and 87.10%, respectively, compared to GLS. Using LVEF as a reference, we obtained AUC of 0.70 and 0.82, and at the best cut-off point (-0.11 and 0.61), sensitivities of 75.00% and 50.00% and specificities of 72.97% and 78.38%, respectively. Conclusion: LLD demonstrated similar performance to that of GLS. MD derived from LLD was the best parameter during systole, while MVED was the best during diastole. Our findings demonstrate the routine, quick, and inexpensive assessment of diastolic function on CMR.(AU)


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Stroke Volume/physiology , Echocardiography/methods , Ventricular Function, Left , Aortic Valve Disease/diagnosis , Myocardial Contraction/physiology , Aortic Valve Insufficiency/diagnostic imaging , Blood Flow Velocity , Magnetic Resonance Spectroscopy/methods , Heart Ventricles/pathology
3.
Rev. bras. cir. cardiovasc ; 36(1): 130-132, Jan.-Feb. 2021. tab, graf
Article in English | LILACS | ID: biblio-1155797

ABSTRACT

Abstract Aortic valve endocarditis can lead to secondary involvement of aorto-mitral curtain and the adjacent anterior mitral leaflet (AML). The secondary damage to AML is often caused by the infected jet of aortic regurgitation hitting the ventricular surface of the mitral leaflet, or by the pronounced bacterial vegetation that prolapses from the aortic valve into the left ventricular outflow tract. This is called 'kissing lesion'. We describe a patient with infective endocarditis of the aortic valve causing perforation of both noncoronary cusp of aortic valve and the AML, which is rare.


Subject(s)
Humans , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/diagnostic imaging , Endocarditis, Bacterial/surgery , Endocarditis, Bacterial/complications , Endocarditis, Bacterial/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve Insufficiency
5.
Rev. chil. cardiol ; 39(3): 256-260, dic. 2020. ilus
Article in Spanish | LILACS | ID: biblio-1388062

ABSTRACT

Resumen: Un hombre de 66 años portador de una prótesis valvular aórtica SJM Biocor® (Saint Jude Medical, St Paul, Minn), instalada 6 años antes, se presentó con disnea severa de rápida instalación. Mediante ecocardiografía de superficie y transesofágica se demostró insuficiencia aórtica masiva y el paciente fue reintervenido con éxito. En la operación se observó un desprendimiento parcial de la inserción del velo coronario izquierdo al anillo protésico. No había endocarditis. Se implantó una nueva prótesis biológica Trifecta® (Saint Jude Inc, St Paul, Minn) N°27. La evolución precoz y a 2 años de la intervención es muy satisfactoria.


Abstract A 66 year-old man with a SJM Biocor® (Saint Jude Medical, St Paul, Minn) implanted 6 years before developed unexpected severe dyspnea. Surface and transesophageal echocardiograms confirmed severe aortic regurgitation. The patient was rapidly re operated on. There was a partial detachment of the left coronary leaflet form the valve annulus. There was no evidence of endocarditis. A new valve (Trifecta® (Saint Jude Inc, St Paul, Minn) N°27). was inserted. Clinical course has been uneventful up to two years post surgery.


Subject(s)
Humans , Male , Aged , Aortic Valve Insufficiency/etiology , Rupture, Spontaneous/complications , Heart Valve Prosthesis/adverse effects , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Reoperation , Bioprosthesis/adverse effects , Echocardiography, Transesophageal
6.
Rev. bras. cir. cardiovasc ; 35(4): 573-576, July-Aug. 2020. tab, graf
Article in English | LILACS, SES-SP | ID: biblio-1137288

ABSTRACT

Abstract Left sinus of Valsalva aneurysm (SVA) is a very infrequent clinical entity. Valsalva aneurysms are often asymptomatic in right and non-coronary sinuses and the diagnosis is often incidental. A left SVA which presents with exertional chest pain due to compression of left coronary system arteries is extremely rare. In this case, we present a successful surgical repair of left SVA without aortic regurgitation or myocardial infarction in a 59-year-old male patient.


Subject(s)
Humans , Male , Middle Aged , Aortic Aneurysm/surgery , Aortic Aneurysm/complications , Aortic Aneurysm/diagnostic imaging , Sinus of Valsalva/surgery , Sinus of Valsalva/diagnostic imaging , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Chest Pain/etiology , Myocardial Infarction
7.
Arq. bras. cardiol ; 115(2): 253-260, ago., 2020. tab, graf
Article in English, Portuguese | LILACS, SES-SP | ID: biblio-1131283

ABSTRACT

Resumo Fundamento A ecocardiografia é essencial para o diagnóstico e a quantificação da insuficiência aórtica (IA). A integral velocidade-tempo (IVT) do fluxo da IA pode estar relacionada à gravidade da IA. Objetivo Este estudo tem por objetivo avaliar se a IVT é um marcador ecocardiográfico de gravidade da IA. Métodos Foram incluídos todos os pacientes com IA nativa moderada ou grave e ritmo sinusal que visitaram o nosso laboratório de imagem entre janeiro e outubro de 2016. Todos os indivíduos foram submetidos a um ecocardiograma completo com medição da IVT da IA. A associação entre a IVT e a gravidade da IA foi analisada por regressão logística e modelos de regressão multivariada. Valores p<0,05 foram considerados estatisticamente significativos. Resultados Entre os 62 pacientes incluídos (68,5±14,9 anos; 64,5%: IA moderada; 35,5%: IA grave), a IVT foi maior em indivíduos com IA moderada em comparação àqueles com IA grave (2,2±0,5 m versus 1,9±0,5 m, p=0,01). Pacientes com IA grave apresentaram valores maiores de diâmetro diastólico final do ventrículo esquerdo (DDFVE) (56,1±7,1 mm versus 47,3±9,6 mm, p=0,001), volume diastólico final do ventrículo esquerdo (VDFVE) (171±36,5 mL versus 106±46,6 mL, p<0,001), orifício regurgitante efetivo (0,44±0,1 cm2 versus 0,18±0,1 cm2, p=0,002) e volume regurgitante (71,3±25,7 mL versus 42,5±10,9 mL, p=0,05), assim como menor fração de ejeção do ventrículo esquerdo (FEVE) (54,1±11,2% versus 63,2±13,3%, p=0,012). A IVT mostrou ser um marcador de gravidade da IA, independentemente do DDFVE, VDFVE e FEVE ( odds ratio 0,160, p=0,032) e da frequência cardíaca e pressão arterial diastólica (PAD) ( odds ratio 0,232, p=0,044). Conclusões A IVT do fluxo da IA apresentou associação inversa com a gravidade da IA, independentemente do diâmetro e volume do ventrículo esquerdo, frequência cardíaca, PAD e FEVE. A IVT pode ser um marcador de gravidade da IA em pacientes com IA nativa e ritmo sinusal. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Abstract Background Echocardiography is essential for the diagnosis and quantification of aortic regurgitation (AR). Velocity-time integral (VTI) of AR flow could be related to AR severity. Objective This study aims to assess whether VTI is an echocardiographic marker of AR severity. Methods We included all patients with moderate or severe native AR and sinus rhythm who visited our imaging laboratory from January to October 2016. All individuals underwent a complete echocardiogram with AR VTI measurement. The association between VTI and AR severity was analyzed by logistic regression and multivariate regression models. A p-value<0,05 was considered statistically significant. Results Among the 62 patients included (68.5±14.9 years old; 64.5%: moderate AR; 35.5%: severe AR), VTI was higher in individuals with moderate AR compared to those with severe AR (2.2±0.5 m vs. 1.9±0.5 m, p=0.01). Patients with severe AR presented greater values of left ventricular end-diastolic diameter (LVEDD) (56.1±7.1 mm vs. 47.3±9.6 mm, p=0.001), left ventricular end-diastolic volume (LVEDV) (171±36.5 mL vs. 106±46.6 mL, p<0.001), effective regurgitant orifice (0.44±0.1 cm2vs. 0.18±0.1 cm2, p=0.002), and regurgitant volume (71.3±25.7 mL vs. 42.5±10.9 mL, p=0.05), as well as lower left ventricular ejection fraction (LVEF) (54.1±11.2% vs. 63.2±13.3%, p=0.012). The VTI proved to be a marker of AR severity, irrespective of LVEDD, LVEDV, and LVEF (odds ratio 0.160, p=0.032) and of heart rate and diastolic blood pressure (DBP) (odds ratio 0.232, p=0.044). Conclusions The VTI of AR flow was inversely associated with AR severity regardless of left ventricular diameter and volume, heart rate, DBP, and LVEF. VTI could be a marker of AR severity in patients with native AR and sinus rhythm. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)


Subject(s)
Humans , Aged , Aged, 80 and over , Aortic Valve Insufficiency/diagnostic imaging , Stroke Volume , Time , Severity of Illness Index , Echocardiography , Ventricular Function, Left , Middle Aged
9.
Arq. bras. cardiol ; 114(2): 284-292, Feb. 2020. tab, graf
Article in English | LILACS | ID: biblio-1088875

ABSTRACT

Abstract Background: Diastolic dysfunction, commonly evaluated by echocardiography, is an important early finding in many cardiomyopathies. Cardiac magnetic resonance (CMR) often requires specialized sequences that extends the test time. Recently, feature-tracking imaging has been made available, but still requires expensive software and lacks clinical validation. Objective: To assess diastolic function in patients with aortic valve disease (AVD) and compare it with normal controls by evaluating left ventricular (LV) longitudinal displacement by CMR. Methods: We compared 26 AVD patients with 19 normal controls. Diastolic function was evaluated as LV longitudinal displacement in 4-chamber view cine-CMR images using steady state free precession (SSFP) sequence during the entire cardiac cycle with temporal resolution < 50 ms. The resulting plot of atrioventricular junction (AVJ) position versus time generated variables of AVJ motion. Significance level of p < 0.05 was used. Results: Maximum longitudinal displacement (0.12 vs. 0.17 cm), maximum velocity during early diastole (MVED, 0.6 vs. 1.4s-1), slope of the best-fit line of displacement in diastasis (VDS, 0.22 vs. 0.03s-1), and VDS/MVED ratio (0.35 vs. 0.02) were significantly reduced in AVD patients compared with controls, respectively. Aortic regurgitation showed significantly worse longitudinal LV shortening compared with aortic stenosis. Higher LV mass indicated worse diastolic dysfunction. Conclusions: A simple linear measurement detected significant differences on LV diastolic function between AVD patients and controls. LV mass was the only independent predictor of diastolic dysfunction in these patients. This method can help in the evaluation of diastolic dysfunction, improving cardiomyopathy detection by CMR, without prolonging exam time or depending on expensive software.


Resumo Fundamentos: A disfunção diastólica, comumente avaliada por ecocardiografia, é um importante achado precoce na maioria das cardiomiopatias. A ressonância magnética cardíaca (RMC) frequentemente requer sequências específicas que prolongam o tempo de exame. Recentemente, métodos de imagens com monitoramento de dados (feature-tracking) foram desenvolvidos, mas ainda requerem softwares caros e carecem de validação clínica. Objetivos: Avaliar a função diastólica em pacientes com doença valvar aórtica (DVA) e compará-la a controles normais pela medida do deslocamento longitudinal do ventrículo esquerdo (VE) por RMC. Métodos: Nós comparamos 26 pacientes com DVA com 19 controles normais. A função diastólica foi avaliada como uma medida do deslocamento longitudinal do VE nas imagens de cine-RMC no plano quatro câmaras usando a sequência steady state free precession (SSFP) durante todo o ciclo cardíaco com resolução temporal < 50 ms. O gráfico resultante da posição da junção atrioventricular versus tempo gerou variáveis de movimento da junção atrioventricular. Utilizamos nível de significância de p < 0,005. Resultados: Deslocamento longitudinal máximo (0,12 vs. 0,17 cm), velocidade máxima em início de diástole (0,6 vs. 1,4s-1), velocidade máxima na diástase (0,22 vs. 0,03s-1) e a razão entre a velocidade máxima na diástase e a velocidade máxima em diástole inicial (0,35 vs. 0,02) foram significativamente menores nos pacientes com DVA em comparação aos controles normais, respectivamente. Pacientes com insuficiência aórtica apresentaram medidas de encurtamento longitudinal do VE significativamente piores em comparação aqueles com estenose aórtica. O aumento da massa ventricular esquerda indicou pior disfunção diastólica. Conclusões: Esta simples medida linear detectou diferenças significativas na função diastólica do VE entre pacientes com DVA e controles normais. A massa ventricular esquerda foi o único preditor independente de disfunção diastólica nesses pacientes. Este método pode auxiliar na avaliação da disfunção diastólica, melhorando a detecção de cardiomiopatias por RMC sem prolongar o tempo de exame ou depender de caros softwares.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aortic Valve Insufficiency/physiopathology , Aortic Valve Stenosis/physiopathology , Ventricular Dysfunction, Left/physiopathology , Diastole/physiology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Stenosis/diagnostic imaging , Reference Values , Atrioventricular Node/physiopathology , Atrioventricular Node/diagnostic imaging , Time Factors , Bundle of His/physiopathology , Bundle of His/diagnostic imaging , Case-Control Studies , Linear Models , Retrospective Studies , Ventricular Function, Left/physiology , Ventricular Dysfunction, Left/diagnostic imaging , Statistics, Nonparametric , Magnetic Resonance Imaging, Cine/methods
11.
Rev. bras. cir. cardiovasc ; 33(6): 573-578, Nov.-Dec. 2018. tab
Article in English | LILACS | ID: biblio-977481

ABSTRACT

Abstract Introduction: The aim of this study is to investigate the change in the dimension of sinus of Valsalva in patients who underwent supracoronary ascending aorta replacement with aortic valve replacement. Methods: A total of 81 patients who underwent supracoronary ascending aorta replacement with aortic valve replacement were included. Ten of 81 patients died during the follow-up. The patients were divided into three groups according to the aortic valve diseases. Group I (n=17) included patients with bicuspid valves, group II (n=30) included patients with stenotic degenerative valves, and patients with aortic regurgitation constituted group III (n=24). In preoperative and follow-up periods, the sinus of Valsalva diameter of the patients was evaluated by echocardiographic examination. The mean age was 54.1±15.1 years. Twenty-eight (34.6%) patients were female and 12 (14.8%) patients were in New York Heart Association functional class III. Results: There was no early mortality. Late mortality was developed in 10 (12.4%) patients, 8 (9.9%) due to non-cardiac reasons. Late follow-up was obtained in 71 patients with a mean of 60±30.1 months postoperatively. During follow-up, the increase in the diameter of the sinus of Valsalva was significant in Group I (P<0.01), while in Group II and III it was insignificant (P>0.05). Conclusion: To avoid the risks associated with sinus of Valsalva dilatation, it is reasonable to replace the sinus of Valsalva in the setting of aortic valve replacement and ascending aorta replacement for bicuspid aortic valve with a dilated ascending aorta and relatively normal sinuses of Valsalva in young patients.


Subject(s)
Humans , Male , Female , Middle Aged , Aortic Valve/abnormalities , Aortic Valve/surgery , Sinus of Valsalva/surgery , Heart Valve Prosthesis Implantation/methods , Heart Defects, Congenital/surgery , Heart Valve Diseases/surgery , Mitral Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Sinus of Valsalva/diagnostic imaging , Echocardiography , Retrospective Studies , Age Factors , Heart Valve Prosthesis Implantation/mortality , Heart Defects, Congenital/mortality , Heart Defects, Congenital/diagnostic imaging , Heart Valve Diseases/mortality , Heart Valve Diseases/diagnostic imaging , Mitral Valve/diagnostic imaging
12.
Rev. chil. cardiol ; 37(3): 206-211, dic. 2018. tab, graf
Article in Spanish | LILACS | ID: biblio-978002

ABSTRACT

Resumen: La insuficiencia aórtica severa aguda (IASA) constituye una emergencia quirúrgica; sus principales causas son la endocarditis infecciosa y la disección aórtica. Existen tres hallazgos ecocardiográficos distintivos de dicha patología, que ayudan al diagnóstico y manejo que son: el cierre prematuro de la válvula mitral (CPVM), la insuficiencia mitral diastólica (IMD) y la apertura prematura de la válvula aórtica (APVA). Estos elementos reflejan el severo aumento de la presión de fin de diástole del ventrículo izquierdo (PFDVI) y, si bien son específicos, no son únicos de dicha patología. A continuación, se reporta el caso de un paciente con IASA. Hombre de 36 años, sin antecedentes, consulta por estado infeccioso asociado a insuficiencia cardíaca aguda. Ingresa en shock cardiogénico y la ecocardiografía muestra: ventrículo izquierdo severamente dilatado con función sistólica conservada, dilatación leve de la aurícula izquierda y una endocarditis de válvula aórtica trivalvar asociado a insuficiencia severa. Se identifica, además, la presencia de CPVM y de IMD hallazgos que evidenciaban la severidad de la lesión y lo agudo de la presentación. Se realizó un recambio valvular aórtico de urgencia con una prótesis biológica con buena evolución postoperatoria.


Abstracts: Severe acute aortic regurgitation (SAAR) constitutes a surgical emergency. Its main causes are infective endocarditis and aortic dissection. Three echocardiographic hallmarks aid in its diagnosis and management, namely: premature opening of the aortic valve (POAV), premature mitral valve closure (PMVC) and diastolic mitral regurgitation (DMR), findings that reflect the great increase in left ventricular end-diastolic pressure. Also, these findings are distinctive but not unique to SAAR. We report a 36-year-old male, without past medical history that refers three weeks of malaise, fever and heart failure. At the emergency department, the patient evolved to cardiogenic shock being admitted to the coronary unit. A transthoracic and transesophageal echocardiography revealed a severely dilated left ventricle with normal systolic function, a mild left atrium enlargement and endocarditis of a trileaflet aortic valve with severe regurgitation. Furthermore, PMVC and DMR were identified, findings that portrayed the severe and acute presentation of the disease. A surgical aortic valve replacement was performed uneventfully, and the patient discharged in good conditions.


Subject(s)
Humans , Male , Adult , Aortic Valve Insufficiency/diagnostic imaging , Echocardiography/methods , Aortic Valve Insufficiency/surgery , Acute Disease , Heart Valve Prosthesis Implantation , Heart Valve Diseases/diagnostic imaging , Mitral Valve/surgery , Mitral Valve/diagnostic imaging
13.
Arq. bras. cardiol ; 111(2): 193-202, Aug. 2018. tab, graf
Article in English, Portuguese | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-950218

ABSTRACT

Abstract Background: Balloon post-dilatation (BPD) is often needed for optimizing transcatheter heart valve (THV) implantation, since paravalvular leak (PVL) after transcatheter aortic valve implantation is associated with poor outcome and mortality. Quantitative assessment of PVL severity before and after BPD is mandatory to properly assess PVL, thus improving implantation results and outcomes. Objective: To investigate a quantitative angiographic assessment of aortic regurgitation (AR) by videodensitometry before and after BPD. Methods: Videodensitometric-AR assessments (VD-AR) before and after BPD were analysed in 61 cases. Results: VD-AR decreased significantly from 24.0[18.0-30.5]% to 12.0[5.5-19.0]% (p < 0.001, a two-tailed p < 0.05 defined the statistical significance). The relative delta of VD-AR after BPD ranged from -100% (improvement) to +40% (deterioration) and its median value was -46.2%. The frequency of improvement, no change, and deterioration were 70% (n = 43), 25% (n = 15) and 5% (n = 3), respectively. Significant AR (VD-AR > 17%) was observed in 47 patients (77%) before and in 19 patients (31%) after BPD. Conclusions: VD-AR after THV implantation provides a quantitative assessment of post-TAVI regurgitation and can help in the decision-making process on performing BPD and in determining its efficacy.


Resumo Fundamento: A pós-dilatação com balão (PDB) é normalmente necessária para otimização do implante da válvula cardíaca transcateter (THV), uma vez que o "escape" ou leak paravalvar (PVL) após implante de valva aórtica transcateter está associada com desfecho ruim e mortalidade. A avaliação quantitativa da gravidade do PVL antes e após a PDB é mandatória para se avaliar adequadamente o PVL e, assim, melhorar os resultados e os desfechos do implante. Objetivo: Investigar uma avalição angiográfica quantitativa da regurgitação aórtica (RA) por videodensitometria (VD-RA) antes e após a PDB. Métodos: Resultados da VD-RA antes e após a PDB foram analisados em 61 casos. Resultados Houve diminuição significativa da VD-RA de 24,0(18,0-30,5)% para 12,0(5,5-19,0)% (p < 0,001; p < 0,05 bilateral foi definido como significância estatística). O delta relativo de VD-RA após a PDB variou de -100% (melhora) a +40% (piora) e o valor mediano foi -46,2%. As frequências de melhora, ausência de mudança, e piora foram 70% (n = 43), 25% (n = 15) e 5% (n = 3), respectivamente. Observou-se RA significativo (VD-RA > 17%) em 47 pacientes (77%) antes e em 19 pacientes (31%) após a PDB. Conclusões: A VD-RA após o implante de THV possibilita a avaliação quantitativa da regurgitação pós-TAVI, e pode auxiliar na tomada de decisão quanto à realização ou não da PDB, bem como na avaliação de sua eficácia.


Subject(s)
Humans , Male , Female , Aged, 80 and over , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/diagnostic imaging , Transcatheter Aortic Valve Replacement , Postoperative Complications/diagnostic imaging , Video Recording , Severity of Illness Index , Aortography , Densitometry , Transcatheter Aortic Valve Replacement/adverse effects
15.
Rev. chil. cardiol ; 36(2): 116-121, 2017. ilus, graf
Article in Spanish | LILACS | ID: biblio-899575

ABSTRACT

La insuficiencia aórtica consiste en el reflujo diastólico de sangre desde la aorta hacia el ventrículo izquierdo, sus mecanismos son múltiples y su magnitud queda determinada por: el área del orificio regurgitante, el gradiente diastólico entre la aorta y el ventrículo izquierdo y la duración de la diástole. En contraposición a esto la insuficiencia aórtica sistólica (IAS) es un fenómeno inusual, con escasos reportes y con una fisiopatología particular. Reportamos tres casos clínicos que ilustran los mecanismos de la IAS. CASO 1: Hombre 54 años, consulta por palpitaciones y disnea, la ecocardiografía transtorácica (ETT) objetiva hipertrofia ventricular izquierda leve con buena función y una valvulopatía aórtica degenerativa con insuficiencia leve, durante el examen se registran ex-trasístoles ventriculares aislados asociado a IAS. CASO 2: Hombre de 61 años con diagnóstico de miocardiopatía dilatada no isquémica en estadio D. Su ETT basal evidencia severa dilatación y disfunción ventricular izquierda (FEVI 19%, DTD 90 mm), insuficiencia mitral funcional severa e insuficiencia aórtica leve. Por dependencia a infusión de inótropos se implanta en Marzo del 2016 un dispositivo de asistencia ventricular izquierda HeartWa-re, en control ambulatorio el dispositivo funcionaba normalmente y el ETT objetiva una significativa disminución de los diámetros del ventrículo izquierdo (DTD 70 mm) una válvula aórtica con apertura intermitente asociado a una IAS en rango leve a moderado. CASO 3: Mujer de 82 años con insuficiencia cardíaca y severa disfunción y dilatación ventricular izquierda, se hospitaliza por infección respiratoria, un ETT muestra insuficiencia mitral funcional severa asociado a IAS moderada.


Aortic regurgitation is a diastolic event in which blood from the aorta regurgitates back to the left ventricle, with several possible mechanisms. Its magnitude is determined by: the regurgitant orifice area, the diastolic gradient between the aorta and the left ventricle and the duration of diastole. In contrast, systolic aortic regurgitation (SAR) is an unusual phenomenon with few cases reported in the literature and with a particular pathophysiology. We report three cases of SAR that illustrate its mechanisms. CASE 1: 54 years-old hypertensive male, refers dyspnea associated with irregular heartbeatsTrans-thoracic echocardiography (TTE) revealed a mild left ventricular hypertrophy with normal function along with a degenerative aortic valve that presented mild regurgitation, isolated premature ventricular contractions were frequently observed associated with mild SAR. CASE 2. 61 years-old diabetic male, with a long history of stage D dilated non ischemic cardiom-yopathy. His last TTE was remarkable for a severe left ventricular dilatation and dysfunction (LVEF 19%, EDD 90 mm), severe functional mitral regurgitation, mild aortic regurgitation and pulmonary hypertension (SPAP 60 mmHg) along with right ventricular dysfunction. Because of inotrope infusion dependency a left ventricular assist device (LVAD) Heartware was implanted. At six months outpatient control, LVAD presented normal function parameters and TTE showed significant reduction in left ventricle diameters (EDD 70 mm) along with mild to moderate SAR. CASE 3: 82 year-old female, longstanding heart failure with severe LV dilatation and dysfunction (LVEF 15%), admitted for a respiratory infection, TTE showed moderate SAR along with functional severe mitral regurgitation.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Systole , Echocardiography
16.
Rev. chil. cardiol ; 36(2): 122-126, 2017. ilus
Article in Spanish | LILACS | ID: biblio-899576

ABSTRACT

The quadricuspid aortic valve is a rare congenital anomaly, usually presenting as an isolated malformation causing aortic regurgitation in the faith or sixth decades of life. The first reported cases were found at autopsy or became evident by surgical findings. However, the emergence of new imaging modalities currently allows an earlier diagnosis, including in asymptomatic patients. Hereby the case of a 60-year-old woman with quadricuspid aortic valve diagnosed by echocardiography is presented. A brief discussion of the disease is included.


Subject(s)
Humans , Female , Middle Aged , Aortic Valve/abnormalities , Aortic Valve Insufficiency/congenital , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Echocardiography , Heart Defects, Congenital/complications
17.
Rev. chil. cardiol ; 35(1): 32-40, 2016. ilus, tab, graf
Article in Spanish | LILACS | ID: lil-782640

ABSTRACT

Introducción: La Insuficiencia Aórtica (IA) excepcionalmente es susceptible de reparación. Una de estas excepciones es la Válvula Aórtica Bicúspide (VAB). Objetivo: Analizar nuestros resultados de la reparación de la VAB insuficiente. Método: Se revisó la Base de Datos para el período enero 1994 a Julio 2014. Se identificaron 29 pacientes y se revisaron las fichas clínicas y protocolos operatorios. La supervivencia se certificó en el Registro Civil e Identificación de Chile. Resultados: Todos los pacientes fueron hombres. La edad promedio fue 39,4 años (19- 61 años). Cinco pacientes presentaban una endocarditis. El ecocardiograma preoperatorio demostró IA severa en 25 casos (86%) y moderada en 4. El diámetro sis-tólico fue 44 ± 7,1 mm y el diastólico 67,8 ± 6,7 mm. La fracción de acortamiento fue 35,96 ± 5,54%. En todos los casos la VAB presentaba fusión del velo coronariano izquierdo y derecho con rafe medio; en 3, el rafe era incompleto produciéndose un cleft. En 23 casos (79%) la IA era secundaria a prolapso del velo fusionado, en 3 a perforación de velo, en 1 a un cleft y en 2 a perforación y cleft. En 23 casos (79%) se efectuó una resección triangular y en 16 (55%) se complementó con una anuloplastía. En 3 se cerró una perforación y en otros 3 se efectuó un cierre primario de cleft. En 10 casos se realizó un procedimiento asociado. En todos los casos se realizó un ecocardiograma transesofágico intra-operato-rio. En 35% no hubo insuficiencia aórtica residual y en 65% esta fue mínima o leve. No hubo mortalidad operatoria. El seguimiento se completó en el 100%. Dos pacientes (7%) fallecieron por causas no cardiacas. Siete (24%) fueron re-operados, en promedio a los 7,14 años. La media de supervivencia fue 19,3 años (IC95% 17,6-21) y la supervivencia libre de re-operación 15,8 años (IC95% 13-18,7), a 20,6 años de seguimiento. El ecocardiograma efectuado en promedio a los 4,9 años demostró una reducción del diámetro sistólico de 6,15 ± 7,2 mm (p<0,05), del diastólico de 11,26 ± 8,7 mm (p<0,05) y de la fracción de acortamiento de 1,12 ± 5,57% (p<0,33). De los 22 pacientes no reoperados, 9 no tenían IA, en 6 esta era leve (1+) y en 3 leve a moderada (2+); 4 pacientes tenían una estenosis aórtica leve. Conclusión: La reparación quirúrgica de la válvula aortica bicúspide insuficiente tiene baja mortalidad peri-operatoria y excelente supervivencia alejada. Si bien el 24% de los pacientes requirió una re-operación, esta fue tardía en la mayoría de los casos.


Background: Aortic insufficiency (AI) is rarely amenable to surgical repair. One of the exceptions to that statement is the bicuspid aortic valve Aim: to analyze our results in the repair of a regur-gitant bicuspid aortic valve Method: A review of the cardiac surgery data base in the period January 1994 to July 2014 allowed the identification of 29 patients with AI and a bicuspid aortic valve submitted to surgical repair. The data from the clinical record and the surgical report was analyzed. Survival was established from the National Identification Service. Results: all patients were males. Mean age was 39.4 years (range 19-61). Five patients had infective endocarditis. Preoperative echocardiography revealed severe AI in 25 patients (86%) and moderate AI in 4. Left ventricular diastolic and systolic diameters were 67,8 ± 6,7 and 44 ± 7,1 mm, respectively. All patients presented fusion of the left and right leaflets with mid rafhe, and 3 patients had an incomplete rafhe with a cleft. AI was caused by prolapsed fu-sioned leaflet in 23 patients, leaflet perforation in 3, cleft in one and perforation plus cleft in 2 patients. Triangular resection was performed in 23 (79%) and complemented by annuloplasty in 16 (55%) patients. Three patients underwent closure of a perforation and 3 a repair of the cleft. An additional surgical procedure was performed in 10 patients. All patients underwent intra-operative TEE. 35% had no residual AI and 65% had minimal or mild AI. There was no surgical mortality. Follow up was completed in all patients. Two patients (7%) died from non cardiac causes. Seven patients (24%) had to be re-operated on, a mean of 7.1 years after the initial surgery. Mean survival rate was 19.3 (95% CI 17.6-21), and mean survival free from re-operation was 15.8 years (95%CI 13-18.7) at 20.6 years of follow up. Echo-cardiogram performed at a mean of 4.9 years after surgery showed a reduction of LV systolic diameter of 6,15 ± 7,2 mm (p<0,05), LV diastolic diameter of 11,26 ± 8,7 mm (p<0,05) and fractional shortening of 1,12 ± 5,57% (p<0,33). In the group of 22 patients who did not have a re-operation, AI was absent in 9, mild in 6 and moderate in 3; 4 patients had mild aortic stenosis. Conclusion: Surgical repair of the regurgitant bicuspid aortic valve has low peri-operative mortality rate and excellent late survival. Reoperation, required in 24% of patients, occurred late after the initial operation in most cases.


Subject(s)
Humans , Male , Adult , Middle Aged , Young Adult , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Plastic Surgery Procedures/methods , Aortic Valve/diagnostic imaging , Aortic Valve Insufficiency/mortality , Aortic Valve Insufficiency/diagnostic imaging , Echocardiography , Survival Analysis , Treatment Outcome
19.
Korean Journal of Radiology ; : 169-177, 2010.
Article in English | WPRIM | ID: wpr-127080

ABSTRACT

OBJECTIVE: This study compared the area of the regurgitant orifice, as measured by the use of multidetector-row CT (MDCT), with the severity of aortic regurgitation (AR) as determined by the use of echocardiography for AR. MATERIALS AND METHODS: In this study, 45 AR patients underwent electrocardiography-gated 40-slice or 64-slice MDCT and transthoracic or transesophageal echocardiography. We reconstructed CT data sets during mid-systolic to enddiastolic phases in 10% steps (20% and 35-95% of the R-R interval), planimetrically measuring the abnormally opened aortic valve area during diastole on CT reformatted images and comparing the area of the aortic regurgitant orifice (ARO) so measured with the severity of AR, as determined by echocardiography. RESULTS: In the 14 patients found to have mild AR, the ARO area was 0.18+/-0.13 cm2 (range, 0.04-0.54 cm2). In the 15 moderate AR patients, the ARO area was 0.36 +/- 0.23 cm2 (range, 0.09-0.81 cm2). In the 16 severe AR patients, the ARO area was 1.00 +/- 0.51 cm2 (range, 0.23-1.84 cm2). Receiver-operator characteristic curve analysis determined a sensitivity of 85% and a specificity of 82%, for a cutoff of 0.47 cm2, to distinguish severe AR from less than severe AR with the use of CT (area under the curve = 0.91; 95% confidence interval, 0.84-1.00; p < 0.001). CONCLUSION: Planimetric measurement of the ARO area using MDCT is useful for the quantitative evaluation of the severity of aortic regurgitation.


Subject(s)
Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Young Adult , Aortic Valve/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Area Under Curve , Body Weights and Measures/methods , Echocardiography/methods , Echocardiography, Doppler, Color/methods , Echocardiography, Transesophageal/methods , Electrocardiography , ROC Curve , Retrospective Studies , Sensitivity and Specificity , Severity of Illness Index , Tomography, X-Ray Computed/methods
20.
Ann Card Anaesth ; 2009 Jul; 12(2): 173-III
Article in English | IMSEAR | ID: sea-135183

ABSTRACT

Trans-esophageal echocardiography (TEE) is routinely used in valvular surgery in most institutions. The popularity of TEE stems from the fact that it can supplement or confirm information gained from other methods of evaluation or make completely independant diagnoses. Quantitative and qualitative assessment permits informed decisions regarding surgical intervention, type of intervention, correction of inadequate surgical repair and re-operation for complications. This review summarizes the various methods for quantification of aortic regurgitation and stenosis on TEE. The application of Doppler echo (pulsed wave, continuous wave and color) with two-dimensional echo allows the complete evaluation of AV lesions.


Subject(s)
Algorithms , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Echocardiography , Echocardiography, Doppler , Echocardiography, Transesophageal , Endocardial Cushion Defects/surgery , Endocardial Cushion Defects/diagnostic imaging , Heart Valve Prosthesis Implantation , Hemodynamics/physiology , Humans , Pulmonary Artery/surgery , Pulmonary Veins/abnormalities , Pulmonary Veins/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL